Transmitter default values and ranges (continued)Table E-1:
Type Parameter Default Range Comments
Polarity Active low
Display Backlight on/off On
Backlight intensity 63 0 – 63
Refresh rate 200 millisec-
onds
100 – 10,000
milliseconds
Variable 1 Mass flow rate
Variable 2 Mass total
Variable 3 Volume flow
rate
Variable 4 Volume total
Variable 5 Density
Variable 6 Temperature
Variable 7 Drive gain
Variable 8–15 None
Display totalizer start/stop Disabled
Display totalizer reset Disabled
Display auto scroll Disabled
Display offline menu Enabled
Display offline password Disabled
Display alarm menu Enabled
Display acknowledge all alarms Enabled
Offline password 1234
Auto scroll rate 10 sec
Digital com-
munications
Fault action None
Fault timeout 0 seconds 0.0 – 60.0 sec
Modbus address 1
Modbus ASCII support Enabled
Floating-point byte order 3–4–1–2
Default values and ranges
Configuration and Use Manual 299