12. Click Connect.
Need help? If an error message appears:
Verify the HART address of the transmitter, or poll HART addresses 1–15.
Ensure that you have specified the correct port on your PC.
Check the wiring between the PC and the transmitter.
Ensure that the mA output is powered.
Increase or decrease resistance.
Disable burst mode.
Ensure that the resistor is installed correctly. If the mA output is internally powered
(active), the resistor must be installed in parallel. If the mA output is externally powered
(passive), the resistor must be installed in series.
Ensure that there is no conflict with another HART master. If any other host (DCS or PLC) is
connected to the mA output, temporarily disconnect the DCS or PLC wiring.
Using ProLink III with the transmitter
Configuration and Use Manual 193

Table of Contents

Other manuals for Emerson Micro Motion

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Micro Motion and is the answer not in the manual?

Emerson Micro Motion Specifications

General IconGeneral
CategoryMeasuring Instruments
ManufacturerEmerson
BrandMicro Motion
TypeCoriolis Flow Meter
Output4-20 mA, HART, Foundation Fieldbus, Profibus, Modbus
Power Supply24 V DC
MaterialStainless Steel, Hastelloy
Process ConnectionFlanged, Threaded
CertificationsATEX, IECEx, CSA, SIL
Pressure RatingVaries by model; up to 10, 000 psi (690 bar)
Temperature RangeVaries by model; -400 to 750°F (-240 to 400°C)

Related product manuals