Field Communicator Menu Trees and Fast Keys
January 2018
Reference Manual
00809-0400-4101, Rev BA
Field Communicator Menu Trees and Fast Keys
73
Figure B-3. Configure - Manual Setup
Note
Selections with black circle are only available in HART Revision 7 mode. Selection will not appear in HART
Revision 5 DD.
Home
1 Overview
2 Configure
3 Service Tools
Configure
1 Guided Setup
2 Manual Setup
3 Alert Setup
Display
1 Pressure
2 Scaled Variable
3 Sensor Temperature
4 Percent of Range
5 Analog Output
6 Review Parameters at Start-up
HART
1 Variable Mapping
2 Communication Settings
3 Burst Mode Configuration
Security
1 Security Switch Status
2 External Buttons
3 Configuration Buttons
4 HART Lock
5 LOI Password Protection
Scaled Variable
1 SV Data Points
2 SV Units
3 SV Transfer Function
4 SV Linear Offset
5 SV Cutoff mode
6 SV Low Cutoff
7 Scaled Variable
Process Variables
1 Pressure Setup
2 Sensor Temperature Setup
Pressure Setup
1 Pressure
2 Upper Range Value
3 Lower Range Value
4 Pressure Units
5 Damping
6 AO Transfer Function
Sensor Temperature Setup
1 Sensor Temperature
2 Sensor Temp Units
Device Information
1 Indentification
2 Revision Numbers
3 Sensor Module Info
4 Flange Info
5 Remote Seal Info
Analog Output
1 Set Range Points
2 Range by Applying Pressure
3 Sensor Limits
4 Readings
5 Alarm/Saturation Levels
Identification
1 Tag
2 Long Tag
3 Model
4 Serial Number
5 Date
6 Description
7 Message
8 Model Numbers
9 Manufacturer
LOI Password
1 Password Protection
2 Configure Password
HART Lock
1 Lock Status
2 Lock/Unlock
Variable Mapping
1 Primary Variable
2 Second Variable
3 Third Variable
4 Fourth Variable
Communication Settings
1 Polling Address
2 Change Polling Address
3 Universal Revision
4 Change HART Revision
Burst Mode Configuration
1 Burst Message 1
2 Message 1 Content
3 Message 1 Variable
4 Configure Additional Messages
Message 1 Variable
1 First and Trigger Variable
2 Second Variable
3 Third Variable
4 Fourth Variable
Set Range Points
1 Primary Variable
2 Upper Range Value
3 Lower Range Value
Sensor Limits
1 PV Upper Limit
2 PV Lower Limit
3 PV Minimum Span
Alarm/Saturation Levels
1 Alarm Direction
2 High Alarm
3 High Saturation
4 Low Saturation
5 Low Alarm
6 Config Alarm/Set Levels
Readings
1 Analog Output
2 Percent of Range
Manual Setup
1 Process Variables
2 Analog Output
3 Scaled Variable
4 Display
5 HART
6 Security
7 Device Information
Revision Numbers
1 Universal Revision
2 Device Revision
3 Software Revision
4 Hardware Revision
5 Device Driver Revision
Sensor Module Info
1 Configuration
2 Measurement Type
3 Sensor Range
4 Upper Limit
5 Lower Limit
6 Isolator Material
7 Fill Fluid
Flange Info
1 Process Connection
2 Process Connection Material
3 O-ring Material
4 Drain/Vent Material
Model Numbers
1 Model Number 1
2 Model Number 2
3 Model Number 3
Remote Seal Info
1 Num of Remote Seals
2 Seal Type
3 Fill Fluid
4 Diaphragm Material

Table of Contents