5 – 29
Section 5 • Maintenance/Service
VSS/VSM/VSH/VSSH • Installation, Operation and Maintenance Manual • Emerson • 35391SD
6. Remove four nuts (4), screws (1) and at
washers (2) securing ring mounting guard (5) to
four support brackets (3). Remove ring mounting
guard.
7. Remove ve fasteners (6) from ring mounting
guard (5).
8. Remove four screws (9), lock washers (10) and at
washers (11) securing support brackets (3) from
compressor. Remove support brackets. Discard
lock washers.
Installation
9. Install four at washers (11), new lock washers (10)
and screws (9) to secure support brackets (3) to
compressor. Do not fully tighten.
10. Install ve fasteners (6) to ring mounting guard (5).
11. Install four screws (1), at washers (2) and nuts (4)
to secure ring mounting guard (5) to four support
brackets (3).
12. Tighten nuts (4) and screws (9).
13. Install eight fasteners (6) to lower guard (8).
14. Install two at washers (2) and screws (1) to secure
lower guard (8) to ring mounting guard (5).
15. Install three at washers (2) and screws (1) to se-
cure upper guard (7) to ring mounting guard (5).
16. Install eight at washers (2) and screws (1) to se-
cure upper guard (7) to lower guard (8).
17. Return compressor unit to service.
Coupling Guard Replacement
NOTE
Coupling guards may differ slightly but this
replacement procedure can be used to remove and
install them. The coupling guard assembly described
in this procedure is VPN A27435C.
WARNING
The design, construction, mounting and opening
of coupling guards should be performed following
proper local codes. Failure to comply may result in
serious injury or death.
Removal
Reference Figure 5-19.
1. Shut down compressor unit, see Compressor Unit
Isolation for Maintenance/Service procedure.
2. Remove eight screws (1) and at washers (2) secur-
ing upper guard (7) to lower guard (8).
3. Remove three screws (1) and at washers (2) se-
curing upper guard (7) to ring mounting guard (5).
Remove upper guard.
4. Remove two screws (1) and at washers (2) secur-
ing lower guard (8) to ring mounting guard (5).
Remove lower guard.
5. Remove eight fasteners (6) from lower guard (8).
Figure 5-19. Coupling Guard Assembly
(VPN A27435C shown)
1 2
3 4
5
6
2
1
7
2
1
8
21
9
10
11