4 – 18
Section 4 • Operation
VSS/VSM/VSH/VSSH • Installation, Operation and Maintenance Manual • Emerson • 35391SD
Dual Oil Filter Setup For Oil Filters with
Filter Head Assemblies
It is very important to correctly setup units equipped
with dual oil lters, especially for oil lters that have lter
head assemblies. Otherwise, oil pressure readings will
show incorrectly.
To setup dual oil lters, proceed with the following steps:
NOTE
Inlet Oil Pressure Transducer should only read oil
pressure from active oil lter.
1. Decide which oil lter will be active/in use.
Outlet Oil Filter
Shut-Off Valves
Inlet Oil
Filter
Shut-Off
Valves
Inlet Oil Pressure
Shut-Off Valves
2. Open inlet and outlet oil lter shut-off valves to
active oil lter.
3. Open inlet oil pressure shut-off valve for active oil
lter.
4. Close outlet oil lter shut-off valve to inactive oil
lter.
5. Close inlet oil pressure shut-off valve for inactive oil
lter.
Figure 4-15. Dual Oil Filter Setup for Oil Filters with Manifold Heads

Table of Contents