EasyManua.ls Logo

Emerson Vilter VSS - Valve and Instrument Tagging; Equipment Number Identification

Emerson Vilter VSS
250 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1 – 11
VSS/VSM/VSH/VSSH • Installation, Operation and Maintenance Manual • Emerson • 35391SD
Section 1 • General Information
a-bc-yz = ABC-DEFGH-IJKL
a = ABC, b = DE, c = FGH, y = IJK, z = L
A - Process cell or stage of compressor
B - Unit number in process cell or stage of compression
C - Service in process cell or stage of compression
1 - Gas lines
2 - Coolant lines
3 - Oil lube lines
4 - Refrigerant lines
5 - Condensate lines
6 - Air lines
Valve and Instrument Tagging
D - Measured variable
E - Variable Modiers
F - Readout or passive function
G - Output or active function
H - Function modier
I - Loop number or sequential number
J - Loop number or sequential number
K - Loop number or sequential number
L - Sufx
Sample Tag
105-LSH-300-A
1 - First process cell or stage of compression
0 - First unit number in process cell or stage of
compression
5 - Condensate service
L - Level
S - Switch
H - High
3 - Loop number or sequential number
0 - Loop number or sequential number
0 - Loop number or sequential number
A - Another exactly the same device in the same loop as
105-LSH-300
Equipment Number Identication
101-V-300
Process Cell/Compression
Stage Number
Equipment Type
Series Number
Equipment Type
A - Agitator, Mechanical Mixers, Aerators
B - Blowers
C - Compressors
D - Drivers
E - Heat Exchangers
F - Fans
P - Pumps
R - Reactors
U - Filters, Strainers
V - Vessels, Tanks, Separators, Scrubbers

Table of Contents