EasyManua.ls Logo

Emerson Vilter VSS - Additional Information; Operation and Performance; General Design Requirements; Figure 3-5. Foundation with Housekeeping Pads Dimensions - Top View

Emerson Vilter VSS
250 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3 – 8
Section 3 • Installation
VSS/VSM/VSH/VSSH • Installation, Operation and Maintenance Manual • Emerson • 35391SD
Additional Information
Codes and Standards
Vilter
TM
followed the following codes and standards
when designing your foundation:
ACI
ASTM
ASCE 7
IBC 2006
Operation and Performance
The foundation was designed for:
Outside environment severe exposure
Ambient temperature -10 degrees F to 105 degrees F
Unit weight 20,000 lbs
RPM 3600
Soil bearing capacity 1,500 lbs/sq.ft.
Wind speed 120 MPH
Exposure factor D
Wind importance factor 1.15
Concrete poured on and permanently cast against
the earth
General Design Requirements
The compressor foundation is designed to:
Maintain the compressor in alignment and at proper
elevation.
Minimize vibration and prevents its transmission to
other structures
Provide a permanently rigid support
Provide sufcient depth to dampen vibrations.
CENTER LINE GAS
COMPRESSION
SYSTEM
10'-0"
5'-0"
OVER ALL G.A. LENGTH + 4'-0"
Figure 3-5. Foundation with Housekeeping Pads Dimensions - Top View

Table of Contents