Emerson Vilter VSS - Gaterotor Disassembly (All VSS & VSM Compressors Except VSM 97-127 Compressors)

Emerson Vilter VSS
250 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5 – 50
Section 5 • Maintenance/Service
VSS/VSM/VSH/VSSH • Installation, Operation and Maintenance Manual • Emerson • 35391SD
Gaterotor Disassembly (All VSS & VSM
Compressors Except VSM 97-127
Compressors)
10. To perform gaterotor disassembly, remove gatero-
tor from compressor, see Gaterotor Assembly
Replacement procedure (All VSS-VSM Compressors
Except VSM 301-701 Compressors) or Gaterotor
Assembly procedure (VSM 301-701 Compressors
ONLY).
Gaterotor Blade Removal
11. Remove the snap ring and washer from the gatero-
tor assembly. Lift gaterotor blade assembly off the
gaterotor support, see Figure 5-50.
12. Check damper pin and bushing for excessive wear.
Replace if required.
Figure 5-49. Gaterotor and Shelf Clearance
Check for 0.003-0.004” (0.076- 0.102 mm) clearance
between gaterotor blade and partition.
Figure 5-50. Gaterotor Blade Assembly
7. Check the clearance between the entire gatero-
tor blade and the shelf, rotate the gaterotor
to nd the tightest spot. It should be between
0.003-0.004“ (0.076-0.102 mm). Make ad-
justments, if necessary. It is preferable to shim
the gaterotor blade looser rather than tighter
against the shelf, see Figure 5-49.
8. After clearance has been set install a new O-ring
on bearing housing cover, install cover and tight-
en the bolts to the recommended torque value.
9. Install side cover with a new gasket. Tighten the
bolts to the recommended torque value. The
unit can then be evacuated and leak checked.

Table of Contents