Mounting Gammapilot FMG50 HART
12 Endress+Hauser
• Version PVT 800 :
• Total length A: 1 190 mm (46.85 in)
• Total weight: 15.54 kg (34.26 lb)
• Measuring range length B: 800 mm (32 in)
• Distance C: 41 mm (1.61 in)
• Version PVT 1200 :
• Total length A: 1 590 mm (62.60 in)
• Total weight: 17.94 kg (39.55 lb)
• Measuring range length B: 1 200 mm (47 in)
• Distance C: 41 mm (1.61 in)
• Version PVT 1600 :
• Total length A: 1 990 mm (78.35 in)
• Total weight: 20.14 kg (44.40 lb)
• Measuring range length B: 1 600 mm (63 in)
• Distance C: 41 mm (1.61 in)
• Version PVT 2000 :
• Total length A: 2 390 mm (94.09 in)
• Total weight: 22.44 kg (49.47 lb)
• Measuring range length B: 2 000 mm (79 in)
• Distance C: 41 mm (1.61 in)
• Version PVT 2400 :
• Total length A: 2 790 mm (109.84 in)
• Total weight: 24.74 kg (54.54 lb)
• Measuring range length B: 2 400 mm (94 in)
• Distance C: 41 mm (1.61 in)
• Version PVT 3000 :
• Total length A: 3 390 mm (133.46 in)
• Total weight: 28.14 kg (62.04 lb)
• Measuring range length B: 3 000 mm (118 in)
• Distance C: 41 mm (1.61 in)
The weight data refer to the stainless steel housing versions. The aluminum housing
versions are 2.5 kg (5.51 lb) lighter.
The additional weight for small parts is: 1 kg (2.20 lb)
If using a collimator, pay attention to the documentation SD02822F.
5.1.3 Mounting requirements for level measurements
Conditions
• The Gammapilot FMG50 is mounted vertically for level measurements.
• To facilitate installation and commissioning, the Gammapilot FMG50 can be configured and
ordered with an additional support (order feature 620, option Q4: "Retaining bracket").