Gammapilot FMG50 HART Mounting
Endress+Hauser 13
Examples
A
D E
C
B
1
2
A0037715
A Vertical cylinder; the Gammapilot FMG50 is mounted vertically with the detector head pointing either
downwards or upwards, the gamma radiation is aligned to the measuring range.
B Correct: Gammapilot FMG50 mounted outside the tank insulation
C Incorrect: Gammapilot FMG50 mounted inside the tank insulation
D Conical tank outlet
E Horizontal cylinder
1 Source container
2 Gammapilot FMG50
5.1.4 Mounting requirements for point level measurement
Conditions
For point level detection, the Gammapilot FMG50 is generally mounted horizontally at the
height of the desired level limit.