iTEMP TMT112 Mounting
Endress+Hauser 11
3.4.1 CE/EAC mark, declaration of conformity
The device meets the legal requirements of the EU/EEU guidelines. The manufacturer
confirms that the device is compliant with the relevant guidelines by applying the CE/EAC
mark.
3.4.2
HART
®
protocol certification
The temperature transmitter is registered by the HART
®
FieldComm Group. The device meets
the requirements of the HART
®
Communication Protocol Specifications, Revision 5.
3.5 Transport and storage
Carefully remove all the packaging material and protective covers that are part of the
transported package.
Dimensions and operating conditions: → 32
When storing (and transporting) the device, pack it so that it is reliably protected against
impact. The original packaging offers the best protection.
Storage temperature
DIN rail device: –50 to +100 °C (–58 to +212 °F)
4 Mounting
4.1 Mounting requirements
When mounting and operating the device, please take note of the allowable ambient
temperature → 26.
When using the device in a hazardous area, the limits indicated in the certification must be
adhered to (see control drawing).
4.1.1 Dimensions
The dimensions of the device are provided in the "Technical data" section → 26.
4.1.2 Mounting location
Mounting on DIN rail according to IEC 60715, e.g. in control panel.
4.1.3 Mounting angle
There are no limits as to the angle of mounting.