TMT84 Operation
Endress+Hauser 23
5.3 Operating options
5.3.1 "FieldCare" operating program
FieldCare is Endress+Hauser's FDT-based Plant Asset Management Tool for the configuration and
diagnosis of intelligent field devices. Using status information, FieldCare serves as a simple but
effective tool for monitoring devices. Access to the iTEMP
®
TMT84 occurs exclusively via Profibus
communication.
!
Note!
More information:
to the operating structure see chapter 11.1
on the display of diagnostic information as per NAMUR NE107 Chap. 9.2.2
Detailed information on PROFIBUS
®
PA device parameterization and operation concept can be
found in the BA034S/04 Operating Instructions, “Guidelines for Planning and Commissioning
PROFIBUS
®
DP/PA - Field Communication” which can also be found on the CD-ROM. (Additional
sources: www.endress.com Download).
5.3.2 "SIMATIC PDM" operating program (Siemens)
SIMATIC PDM is a standardized, non-proprietary tool for the operation, configuration,
maintenance and diagnosis of intelligent field devices.
Further information at: www.endress.com
5.3.3 Current device description files
The following table lists the correct device description file for the relevant operating tool and the
source.
PROFIBUS PA protocol (IEC 61158-2, MBP):
Valid for firmware/software: 1.00.zz 1.01.zz See the DEVICE SOFTWARE parameter
PROFIBUS
®
PA device data
Profile version:
3.01 3.02 See the PROFILE VERSION parameter
TMT84 device ID:
Profile ID:
1551
hex
Depending on the profile GSD file
used: 0x9703, 0x9702, 0x9701
or 0x9700
See the DEVICE ID parameter
GSD information:
TMT84 GSD:
Profile GSD:
Bitmaps:
Extended
PA139700.gsd
PA139701.gsd
PA139702.gsd
PA139703.gsd
EH1551_D.bmp
EH1551_N.bmp
EH1551_S.bmp
Compatibility matrix:
| EH3x1551.gsd | EH021551.gsd
1.
00.zz |
OK | STOP*
1.01.zz | OK | OK
*Can be used if the "C1_Read_Write_supp
= 1" entry in the GSD is set to
"C1_Read_Write_supp = 0".
Operating program/device driver: Source for device descriptions/program updates, free downloads on
Internet:
GSD www.endress.com ( Download Software Device Drivers)
www.profibus.com
FieldCare/DTM www.endress.com ( Download Software Device Drivers)
SIMATIC PDM www.endress.com ( Download Software Device Drivers)