EasyManua.ls Logo

Endress+Hauser iTEMP TMT84 - Page 92

Endress+Hauser iTEMP TMT84
102 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11 Operation using PROFIBUS
®
PA TMT84
92 Endress + Hauser
11.4.5 Transducer Block slot 2
Transducer Block slot 2 contains the same parameters as Transducer Block slot 1. The settings in
slot 2 affect sensor input 2.
POLY_COEFF_B 153 X X Simple Float 4 S M
POLY_COEFF_C 154
X X Simple Float 4 S M
POLY_COEFF_R0 155
X X Simple Float 4 S M
POLY_MEAS_RANGE_MAX 156
X - Simple Float 4 S M
POLY_MEAS_RANGE_MIN 157
X - Simple Float 4 S M
not used 158 - 161
CORROSION_DETECTION 162
X X Simple Unsigned 8 2 S M
CORROSION_CYCLES 163
X - Simple Unsigned 8 2 S M
SENSOR_DRIFT_ALERT_VALUE 164
X X Simple Float 4 S M
not used 165 - 168
RJ_MAX_SENSOR_VALUE 169
X - Simple Float 4 N M
RJ_MIN_SENSOR_VALUE 170
X - Simple Float 4 N M
not used 171
TEMPERATURE_THRESHOLD 172
X X Simple Float 4 S M
RJ_OUT 173
X - Record 101 5 D M
SENSOR_RAW_VALUE 174
X - Simple Float 4 D M
not used 175 - 219
VIEW_TRANSDUCER_BLOCK 220 X - Simple
Unsigned16,
DS-37, DS-42,
101,
Unsigned8,
Unsigned8
20 DM
Name
Index
Read
Write
Object
Type
Data
Type
Byte Size
Storage
Class
Parameter
All parameters seeChapter 11.4.4 70-220
Name
Index
Read
Write
Object
Type
Data
Type
Byte Size
Storage
Class
Parameter

Other manuals for Endress+Hauser iTEMP TMT84