Levelflex FMP51, FMP52, FMP54
Endress+Hauser 129
Ex-marking in case of connected FHX50 remote display
If the device is prepared for the remote display FHX50 (product structure: feature 030: Display,
Operation", option L or M), the Ex marking of some certificates changes according to the following
table
12)
:
Feature 010 ("Approval") Feature 030 ("Display, Operation") Ex-marking
BE L or M ATEX II 1D Ex ta [ia] IIIC T
500
xx°C Da
BF L or M ATEX II 1/2 D Ex ta [ia Db] IIIC Txx°C Da/Db
BG L or M ATEX II 3G Ex nA [ia Ga] IIC T6 Gc
BH L or M ATEX II 3G Ex ic [ia Ga] IIC T6 Gc
B3 L or M ATEX II 1/2G Ex d [ia] IIC T6 Ga/Gb,
ATEX II 1/2D Ex ta [ia Db] IIIC Txx°C Da/Db
IE L or M IECEx Ex ta [ia] IIIC T500 xx°C Da
IF L or M IECEx ta [ia Db] IIIC Txx°C Da/Db
IG L or M IECEx Ex nA [ia Ga] IIC T6 Gc
IH L or M IECEx Ex ic [ia Ga] IIC T6 Gc
I3 L or M IECEx Ex d [ia] IIC T6 Ga/Gb,
IECEx Ex ta [ia Db] IIIC Txx°C Da/Db
12) The marking of certificates not mentioned in this table are not affected by the FHX50.