Levelflex FMP51, FMP52, FMP54
50 Endress+Hauser
Nozzle mounting
£150 (6)
H
mm (in)
ø 150 (6)£
A0015122
Permissible nozzle diameter: ≤ 150 mm (6 in).
For larger diameters the near range measuring capability may be reduced.
For nozzles ≥ DN300: →  53.
Permissible nozzle height
7)
: ≤ 150 mm (6 in).
For a larger height the near range measuring capability may be reduced.
Larger nozzle heights may be possible in special cases (see sections "Center rod for FMP51 and
FMP52" and "Rod extension/centering HMP40 for FMP54").
With thermally insulated vessels the nozzle should also be insulated in order to prevent
condensate formation.
7) Larger nozzle heights on request