Mounting Levelflex M FMP40 FOUNDATION Fieldbus
12 Endress+Hauser
Installation in concrete silos
Installation, for example, into a thick concrete ceiling should be made flush with the lower edge.
Alternatively, the probe can also be installed into a pipe that must not protrude over the lower
edge of the silo ceiling. The pipe should kept at a minimum length. Installation suggestions see
diagramm.
L00-FMP4xxxx-17-00-00-en-008
Strong dust generation can lead to build-up behind the center washer. This can cause an
intereference signal. For other installation possibilities please contact Endress+Hauser.
2.3.7 Installation in bulk solids silo
Tensile load
Bulk solids exert tensile forces on rope probes whose height increases with:
the length of the probe, i.e. max. cover
the bulk density of the product
the silo diameter
the diameter of the probe rope
100 mm 100 mm
ø80...150 mm
metal
Extension rod /
Centering
(see accessories)
metal tube