Wiring Levelflex M FMP41C with HART/4...20 mA
26 Endress + Hauser
Overvoltage protection
If the measuring device is used for the level measurement in flammable liquids which requires the
use of an overvoltage protection according to DIN EN 60079-14, standard for testprocedures DIN
IEC 60060-1 (10 kA, Puls 8/20 µs) it has to be ensured that
• the measuring device with integrated overvoltage protection with gas discharge tubes within the
T12-enclosure is used, refer to product overview on → ä 8
or
• this protection is achieved by the use of other appropriate measures (external protection devices
e.g. HAW262Z).
4.2.1 HART connection with Endress+Hauser RMA422 / RN221N
L00-FMR2xxxx-04-00-00-en-009
4.2.2 HART connection with other supplies
L00-FMR2xxxx-04-00-00-en-008