EasyManua.ls Logo

Endress+Hauser Levelflex M FMP45 - Page 66

Endress+Hauser Levelflex M FMP45
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical data Levelflex M FMP40 and FMP45
66
Influence of ambiente
temperature
The measurements are carried out in accordance with EN 61298-3:
digital output (HART):
average T
K
: 0.6 mm/10 K, max. ±3.5 mm over the entire temperature range -40 °C...+80 °C
2-wire
Current output (additional error, in reference to the span of 16 mA):
Zero point (4 mA)
average T
K
: 0.032 %/10 K, max. 0.35 % over the entire temperature range -40 °C...+80 °C
Span (20 mA)
average T
K
: 0.05 %/10 K, max. 0.5 % over the entire temperature range -40 °C...+80 °C
4-wire
Current output (additional error, in reference to the span of 16 mA):
Zero point (4 mA)
average T
K
: 0.02 %/10 K, max. 0.29 % over the entire temperature range -40 °C...+80 °C
Span (20 mA)
average T
K
: 0.06 %/10 K, max. 0.89 % over the entire temperature range -40 °C...+80 °C
11.1.4 Operating conditions: Environment
Ambient temperature range Ambient temperature for the transmitter: -40 °C ... +80 °C (-40 °F … +176 °F)
The functionality of the LCD display may be limited for temperatures
Ta<-20 °C and Ta>+60 °C.
A weather protection cover should be used for outdoor operation if the instrument is exposed to
direct sunlight.
Ambient temperature limits FMP40
If temperatures above 80 °C are present at the process connection, the permitted ambient
temperature is reduced according to the following diagram (temperature derating):
L00-FMP40xxx-05-00-00-en-001
T [°C]
T [°C]
-40 0 50
-40
0
40
60
80
100
150
80
max. process connection temperature
max. ambient temperature
80 °C with separate
housing
75 °C with distance
sleeve
65 °C standard compact
F12/T12 housing
60 °C standard compact
F23 housing

Other manuals for Endress+Hauser Levelflex M FMP45