EasyManua.ls Logo

Endress+Hauser Levelflex M FMP45 - Page 71

Endress+Hauser Levelflex M FMP45
80 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Levelflex M FMP40 and FMP45 Technical data
71
11.1.7 Certificates and approvals
CE approval The measuring system meets the legal requirements of the EC-guidelines. Endress+Hauser confirms
the instrument passing the required tests by attaching the CE-mark.
Ex approval Correlation of safety instructions (XA) to the instrument:
Overspill protection WHG. See "Ordering structure" on Page 6- (see ZE 256F/de).
Telecommunication Fulfils "Part 15" of the FCC regulations for an "Unintentional Radiator". All probes meet the
requirements for a "Class A Digital Device".
In addition to this, all probes in metallic tanks meet the requirements for a "Class B Digital Device".
External standards and
guidelines
EN 60529
Protection class of housing (IP-code)
EN 61010
Safety regulations for electrical devices for measurement, control, regulation and laboratory use.
EN 61326
Emissions (equipment class B), compatibility (appendix A - industrial area)
NAMUR
Standards committee for measurement and control in the chemical industry
KEMA 02 ATEX 1109
Certificate ATEX marking Explosion protection Output Remarks XA
1 II 1/2 G EEx ia IIC T6 B 2W, F12, HART XA164F
2W, F23 HART XA211F
2W, T12-OVP HART XA215F
D, F 2W, F12, PA, FF XA165F
2W, F23 PA/FF XA212F
2W, T12-OVP PA, FF XA216F
7 II 1/2 G EEx d [ia] IIC T6 B, D, F 2W, T12, HART, PA, FF XA166F
2 II 1/2 D IP6x, T 115 °C Output: EEx ia IIB G, H 4W, F12, Alu-cover XA168F
EEx ia IIC T6 IP6x, T 83 °C B, D, F 2W, F12, Alu-cover XA172F
IP6x, T 80 °C B, D, F 2W, T12, Alu-cover XA173F
EEx ia IIC T6 IP6x, T 85 °C B, D, F 2W F23, HART, PA, FF XA213F
EEx ia IIC T6 IP6x, T 84 °C B, D, F 2W T12-OVP, HART, PA, FF XA217F
3 II 2 G EEx em [ia] IIC T6 B, D, F 2W, T12, HART, PA, FF XA167F
4 II 1/3 D EEx ia IIC T6 IP6x, T 82 °C B, D, F 2W, F12, HART, PA, FF XA172F
EEx ia IIC T6 IP6x, T 84 °C B, D, F 2W F23, HART, PA, FF XA213F
EEx ia IIC T6 IP6x, T 83 °C B, D, F 2W T12-OVP, HART, PA, FF XA217F
IP6x, T 77 °C B, D, F 2W, T12, HART, PA, FF XA173F
IP6x, T 83 °C Output: EEx ia IIB G, H 4W, F12, HART XA168F
5(8) II 1/2 G, II 1/3 D (+WHG) EEx ia IIC T6 IP6x, T 82 °C B, D, F 2W, F12, HART, PA, FF XA172F
EEx ia IIC T6 IP6x, T 84 °C B, D, F 2W, F23, HART, PA, FF XA213F
EEx ia IIC T6 IP6x, T 83 °C B, D, F 2W, T12-OVP, HART, PA, FF XA217F

Other manuals for Endress+Hauser Levelflex M FMP45

Related product manuals