Liquiphant M FTL50(H), FTL51(H)
Endress+Hauser 11
Electronic insert FEL54 (AC/DC with relay output)
Power supply Supply voltage: 19…253 V AC, 50/60 Hz or 19…55 V DC
Power consumption: max. 1.3 W
Reverse polarity protection
Overvoltage protection FEL54: overvoltage category III
Electrical connection Universal current connection with relay output
Output signal
Signal on alarm Output signal on power failure or in the event of damaged sensor: relay de-energised
Connectable load Loads switched via 2 floating change-over contacts (DPDT)
I~ max. 6 A (EEx d 4 A), U~ max. 253 V AC; P~ max. 1500 VA, cos ϕ = 1, P~ max. 750 VA, cos ϕ > 0.7
•I% max. 6 A (EEx d 4 A) to 30 V, I% max. 0.2 A to 125 V
When connecting a low-voltage circuit with double isolation according to IEC 1010 the following applies:
total of voltages of relay output and power supply max. 300 V
Power supply:
Please note the different voltage ranges
for AC and DC.
Output:
When connecting an instrument with
high inductance, provide a spark arrester
to protect the relay contact.
A fine-wire fuse (depending on the
load connected) protects the relay
contact on short-circuiting.
Both relay contacts switch simultaneously.
* When jumpered, the relay
output works with NPN logic.
** See below "Connectable load"
L00-FTL5xxxx-04-05-xx-xx-002
L1
L+
a
NO
a
NO
u
C
u
C
N
L–
r
NC
r
NC
0.5 A
PE
(Ground)
*
** **
12 678345
FEL54
U~ 19…253 V AC, 50/60 Hz
U– 19… 55 V DC
...
Safety mode Level Output signal LEDs
green red
L00-FTL2xxxx-07-05-
xx-xx-001
= relay energised
= relay de-energised
= lit
= unlit
L00-FTL5xxxx-04-05-xx-xx-005
Max.
Min.
354
354
687
687
354
354
687
687

Table of Contents