Proline Promag 53 FOUNDATION Fieldbus
4 Endress+Hauser
<
Temperature tables
Measuring system Promag 53 W/P/H (compact version)
Sensor Promag W/P/H (remote version)
* The IP 68 version is limited to 130 °C.
at T
a
= 40 °C Max. medium temperature [°C] in
T6
85 °C
T5
100 °C
T4
135 °C
T3
200 °C
T2
300 °C
T1
450 °C
Promag H DN 2...100 80 95 130 150 150 150
Promag P DN 25...200 (PFA lining) 80 95 130 150 150 150
Promag P DN 15...600 (PTFE lining) 80 95 130 130 130 130
Promag W DN 65...1200 (hard rubber lining) 80 80 80 80 80 80
at T
a
= 45 °C Max. medium temperature [°C] in
T6
85 °C
T5
100 °C
T4
135 °C
T3
200 °C
T2
300 °C
T1
450 °C
Promag H DN 2...100 80 95 130 130 130 130
Promag P DN 25...200 (PFA lining) 80 95 130 130 130 130
Promag P DN 15...600 (PTFE lining) 80 95 130 130 130 130
Promag W DN 65...1200 (hard rubber lining) 80 80 80 80 80 80
at T
a
= 50 °C Max. medium temperature [°C] in
T6
85 °C
T5
100 °C
T4
135 °C
T3
200 °C
T2
300 °C
T1
450 °C
Promag H DN 2...100 80 95 95 95 95 95
Promag P DN 25...200 (PFA lining) 80 95 95 95 95 95
Promag P DN 15...600 (PTFE lining) 80 95 95 95 95 95
Promag W DN 65...1200 (hard rubber lining) 80 80 80 80 80 80
at T
a
= 50 °C Max. medium temperature [°C] in
T6
85 °C
T5
100 °C
T4
135 °C
T3
200 °C
T2
300 °C
T1
450 °C
Promag H DN 2...100 80 95 130 150 150 150
Promag P DN 25...200 (PFA lining) 80 95 130 150 * 150 * 150 *
Promag P DN 15...600 (PTFE lining) 80 95 130 130 130 130
Promag W DN 65...1200 (hard rubber lining) 80 80 80 80 80 80
at T
a
= 60 °C Max. medium temperature [°C] in
T6
85 °C
T5
100 °C
T4
135 °C
T3
200 °C
T2
300 °C
T1
450 °C
Promag H DN 2...25 80 95 130 130 130 130
Promag H DN 40...100 80 95 130 150 150 150
Promag P DN 25...200 (PFA lining) 80 95 130 130 130 130
Promag P DN 15...600 (PTFE lining) 80 95 130 130 130 130
Promag W DN 65...1200 (hard rubber lining) 80 80 80 80 80 80