Commissioning Proline Prosonic Flow B 200 HART
88 Endress+Hauser
Parameter overview with brief description
Parameter Prerequsite Description Selection / User
entry
Factory setting
Format display A local display is provided. Select how measured values
are shown on the display.
1 value, max. size
1 bargraph + 1
value
2 values
1 value large + 2
values
4 values
1 value, max. size
Value 1 display A local display is provided. Select the measured value that
is shown on the local display.
Volume flow
Corrected volume
flow
Corrected methane
volume flow
*
Mass flow
Energy flow
*
Methane fraction
*
Calorific value
*
Wobbe index
*
Temperature
*
Totalizer 1
Totalizer 2
Totalizer 3
Current output 1
Current output 2
*
Sound velocity
Flow velocity
Acceptance rate
*
Signal asymmetry
*
Turbulence
*
Signal strength
*
Signal to noise
ratio
*
Volume flow
0% bargraph value 1 A local display is provided. Enter 0% value for bar graph
display.
Signed floating-point
number
Country-specific:
0 m³/h
0 ft³/h
100% bargraph value 1 A local display is provided. Enter 100% value for bar
graph display.
Signed floating-point
number
Depends on country
and nominal
diameter
Decimal places 1 A measured value is specified
in the Value 1 display
parameter.
Select the number of decimal
places for the display value.
x
x.x
x.xx
x.xxx
x.xxxx
x.xx
Value 2 display A local display is provided. Select the measured value that
is shown on the local display.
Picklist see Value 1
display parameter
None
Decimal places 2 A measured value is specified
in the Value 2 display
parameter.
Select the number of decimal
places for the display value.
x
x.x
x.xx
x.xxx
x.xxxx
x.xx
Value 3 display A local display is provided. Select the measured value that
is shown on the local display.
Picklist see Value 1
display parameter
None
0% bargraph value 3 A selection has been made in
the Value 3 display
parameter.
Enter 0% value for bar graph
display.
Signed floating-point
number
Country-specific:
0 m³/h
0 ft³/h
100% bargraph value 3 An option was selected in the
Value 3 display parameter.
Enter 100% value for bar
graph display.
Signed floating-point
number
Depends on country
and nominal
diameter