Operation Proline Prosonic Flow B 200 HART
98 Endress+Hauser
Flow velocity
Process pressure
Parameter overview with brief description
Parameter Prerequsite Description User interface
Volume flow Displays the volume flow currently
measured.
Dependency
The unit is taken from the Volume flow
unit parameter
Signed floating-point
number
Corrected volume flow Displays the corrected volume flow
currently calculated.
Dependency
The unit is taken from the Corrected
volume flow unit parameter
Signed floating-point
number
Corrected methane volume flow For the following order code:
"Sensor version", option 2 "Volume flow
+ biogas analysis"
Displays the methane corrected volume
flow currently calculated.
Dependency
The unit is taken from the Corrected
volume flow unit parameter
Signed floating-point
number
Mass flow Displays the mass flow currently
calculated.
Dependency
The unit is taken from the Mass flow
unit parameter
Signed floating-point
number
Energy flow For the following order code:
"Sensor version", option 2 "Volume flow
+ biogas analysis"
Displays the energy flow currently
calculated.
Dependency
The unit is taken from the Energy flow
unit parameter
Signed floating-point
number
Dry methane in % For the following order code:
"Sensor version", option 2 "Volume flow
+ biogas analysis"
Displays the methane fraction of the
dry gas currently measured.
Signed floating-point
number
Calorific value For the following order code:
"Sensor version", option 2 "Volume flow
+ biogas analysis"
Displays the calorific value currently
calculated.
Dependency
The unit is taken from the Calorific
value unit parameter
Signed floating-point
number
Wobbe index For the following order code:
"Sensor version", option 2 "Volume flow
+ biogas analysis"
Displays the Wobbe index currently
calculated.
Dependency
The unit is taken from the Calorific
value unit parameter
Signed floating-point
number
Temperature For the following order code:
"Sensor version", option 2 "Volume flow
+ biogas analysis"
Displays the temperature currently
calculated.
Dependency
The unit is taken from the
Temperature unit parameter
Signed floating-point
number
Sound velocity Displays the sound velocity currently
measured.
Dependency
The unit is taken from the Velocity
unit parameter
Signed floating-point
number