Installation Proline t-mass 65
12 Endress+Hauser
2.3.2 Turning the local display
2.3.3 Installing the wall-mount housing
"
Caution!
• Make sure that the ambient temperature does not exceed the permitted range.
• Always install the wall-mount housing in such a way that the cable entries point downwards.
Mounted directly on the wall
A0007541
a. Press in the side latches on the display module and
remove the module from the cover plate of the
electronics compartment.
b. Turn the display to the desired position (max. 4 x
45° in both directions) and reset it onto the cover
plate of the electronics compartment.
4 x 45°
a
A0007542-ae
1. Connection compartment
2. Securing screws M6 (max. ø 6.5 mm (0.25"); screw
head max. ø 10.5 mm (0.4")
3. Housing bores for securing screws
1
2
3
3
90 (3.54)
35 (1.38)
192 (7.56)
81.5 (3.2)
mm (inch)