EasyManua.ls Logo

Endress+Hauser promag 30 User Manual

Endress+Hauser promag 30
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
promag 30
Electromagnetic
Flow Measuring System
BA 008D/06/e/06.96
No. 50063716
valid from software version
V3.01.XX (measuring amplifier)
Operating Manual
Question and Answer IconNeed help?

Do you have a question about the Endress+Hauser promag 30 and is the answer not in the manual?

Endress+Hauser promag 30 Specifications

General IconGeneral
BrandEndress+Hauser
Modelpromag 30
CategoryMeasuring Instruments
LanguageEnglish

Summary

Safety Instructions

Correct Usage

Guidelines for proper application and use of the Promag 30.

Dangers and Notes

Identifies potential hazards and important notes for safe operation.

Personnel for Installation, Start-up and Operation

Specifies requirements for personnel performing installation, start-up, and operation.

Mounting and Installation

General Information

General guidelines for installation, focusing on IP 67 protection and temperature ranges.

Mounting Instructions

Provides guidance on optimal mounting positions and vibration considerations.

Mounting the sensor

Detailed steps for mounting various Promag sensor types.

Mounting the transmitter (remote-mounted version)

Guidelines for mounting the transmitter remotely from the sensor.

Electrical Connection

Connection to the transmitter

Steps for connecting the supply and signal cables to the transmitter.

Connection of the remote version

Procedures for connecting the remote sensor and transmitter.

Wiring diagrams

Diagrams illustrating the electrical connections for supply, inputs, and outputs.

Operation and Commissioning

Instrument Functions

Overview of various instrument functions configurable via miniature switches.

Status output

Configuration options for the status output (e.g., error signals, flow direction).

Current range

Setting the current output signal for zero and full-scale flow values.

Setting unit parameters with miniature switches

Detailed guide on setting instrument parameters using miniature switches.

Commissioning

Final checks and steps to perform before initial operation of the equipment.

Fault Location and Remedies

Behaviour of the measuring equipment in the event of a fault or alarm

Describes how the system reacts to faults and alarms via outputs and display.

Instructions for fault location and remedies

A flowchart to help diagnose and resolve common faults.