Soliwave FDR56/FQR56
Endress+Hauser 17
Electrical connection
5.2.3 Connection signal circuit
3
4 5
2
3 4
3 4 5
0000000162
11 Connectionsignalcircuit(Connector2)
3
4
~
3 A
4
+
-
A B C
3 (NO)
4 (CC)
5 (NC)
0000000149
12 Signal circuits
Relay output
Switching capacity 250V AC / 4A, 125V DC / 0.4A or 30V DC / 4A
Switching delay parameterizable (o, 500ms to 10s)
Switching hysteresis adjustable
Switching frequency max. 4Hz
Electrical connection Relay output
Connection terminals Terminals 3 (NO) - 4 (CC) - 5 (NC)
M12 connector Binder series 713/763 Connector 2, contact 2 (NO) - 3 (CC) - 4 (NC)
Harting connector type HAN8D Connector 2, contact 3 (NO) - 4 (CC) - 5 (NC)