Chart 3: Malfunctions
Trouble Origin Solution
The dispenser doesn't switch on
Loss of electrical voltage supply. Check electrical connection
Not activated electrical supply
Turn bipolar switch to position I
(ON).
Fuse is burned up. Replace the fuse.
Dispensing tap buttons are off.
Bottle is missing
Engage the bottle in the
dispensing tap
The bottle can't reach the
dispensing tap
Insert one or more spacers to lift
the bottle piston
The bottle doesn't correctly fit
the dispensing tap
Properly fit bottle neck to
dispensing tap
The bottle was engaged when
the dispenser was off
Replace the bottle in the
dispensing tap
One or more dispensing tap
buttons are off.
The wine left in the bottle is not
enough to pour preset volume
Select a different dose or
replace the bottle
The wine is not fluently poured
The straw is not properly
inserted into the dispensing tap
Remove the bottle and firmly
push upwards the straw into the
dispensing tap
The filter of the straw is clog Clean the straw or replace it.
The nitrogen/argon to pour the
wine is run out or supply
pressure is fail
Restore proper nitrogen/argon
duty condition
Some wine drops fall from a
serving spout
Dispensing tap valves are clog
by some wine sediments
Sanitize the dispensing tap
Next to bottle neck pin (bottle
engaged) gas overflows.
The bottle doesn't correctly fit
the dispensing tap
Properly fit bottle neck to
dispensing tap
The bottle can't reach the
dispensing tap
Insert one or more spacers to lift
the bottle piston