Section 11 — Sequencer Parameters TS-12 Musician’s Manual
14
8th
74%
Quantized to
Straight Eighths
Quantize points:
Q = Straight
S = Swing
Time
01 25 49 73 01
with SWING=74
with RANDOM=3
Re-Quantized to
Straight Eighths
16th 16th
at Clock 72
at Clock 75
Event moves
to next 8th!
Clocks
In this example, QUANTIZE is set to 1/8th notes, SWING is set to 74% and RANDOM set to 3,
the event can be moved beyond the Swing Quantize point. In this case, a subsequent straight
eighth quantize will move the event to the eighth note after the one it was initially on.
ERASE
This command will erase notes, controllers and all other data from the entire track, or from a
given range if you so specify.
• Make sure the track you want to erase is selected.
• Press Edit Track, then select ERASE. The display shows:
• If you wish to erase a specific range rather than the entire track, press RANGE and set the time
and/or key range on the Edit Track Range page, as shown earlier in this section. If not, leave
it set to RANGE=ALL.
• Press *YES* to execute the edit command (or press *NO* to cancel). After editing, if a range
was specified, the TS-12 returns with the Audition Play/Keep page where you can audition
the results of the edit before deciding whether to keep it or not. If the range was ALL, there is
no audition.
COPY
This command will copy all or part of the current track (the source track) to another track. The
destination track can be in the same sequence or in a different sequence.
• Make sure the track you want to copy is selected.
• Press Edit Track, then select COPY. The display shows: