55
IP1967EN - 2016-08-01
Display Description
M2 - Setting motor 2 manoeuvre time. [s]
Adjustment, in seconds, of the total manoeuvre time for
motor 2.
Example:
= 7 seconds
= 7,5 seconds
MIN MAX
TR - Setting motor 1 closing delay time. [s]
Adjustment, in seconds, of the delay time for starting the
manoeuvre of motor 1, in relation to motor 2.
MIN MAX
TO - Impostazione tempo di ritardo motore 2 in apertura. [s]
Regolazione in secondi del tempo di ritardo della partenza
di manovra del motore 2 rispetto al motore 1.
MIN MAX
LU - Setting switch-on time for courtesy light. [s]
Adjustment occurs with intervals of varying sensitivity.
- from 0 to 59 sec with 1 sec intervals;
- from 1 to 2 min with 10 sec intervals;
- from 2 to 3 min with 1 min intervals;
NO - Disabled
ON - Permanent switch-on, switch-off using radio
command
i
WARNING: the courtesy light switches on at the start
of each operation.
DISABLED
1 SECOND
1 MINUTE
3 MINUTES
59 SECONDS
2 MINUTES
ON
LG - Setting switch-on time for independent light. [s]
Adjustment occurs with intervals of varying sensitivity.
- from 0 to 59 sec with 1 sec intervals;
- from 1 to 2 min with 10 sec intervals;
- from 2 to 3 min with 1 min intervals;
NO - Disabled
ON - Switch-on and switch-off using radio command
i
WARNING: the switching on of the light does not de-
pend on the start of an operation, but it is possible to
control it separately using the relevant transmitter
key.
DISABLED
1 SECOND
1 MINUTE
3 MINUTES
59 SECONDS
2 MINUTES
ON
i
WARNING: adjustment occurs with a sensitivity in-
terval of 0.5 sec, indicated by the switching on of the
right-hand point.