Envirosight Verisight Pro
+
Technical Details CAM026
Product ID: CAM026
Dimensions: 4.7 x 2.8 x 2.8 inches (L x W x H)
Power Consumption: 10W
Weight: (1.87lb) 0.85Kg
Temperature Range: -4° ~ +122°F (-20°C ~ +50° C)
Environmental Protection: Pressurised
Internal Pressure: 0 to 500mb
Information and Care
Pressurization
The camera module must always be correctly filled with CO
2
or Nitrogen. The
control unit displays the internal pressure.
Cleaning
Ensure the camera module is thoroughly cleaned after each inspection. Ensure
the connector is free from dirt and moisture. Always fit the protective cap
immediately after disconnecting the camera module from the system.
Maintenance
Ensure that all screw threads and connections are free from dirt. Replace the
rubber protectors when worn or damaged.
CAUTION!
High-pressure cleaners must not be used. It can cause
considerable damage to the coiler, camera and other system
components.
Cleaning agents or solvents must not be used. These can damage
the seals and other materials on the system. Only clean water
should be used.