Page #17 background imageLoading...
Page #17 background image
Identification
Accessories (optional)
* It is essential that the unit is protected from being touched.
2.4 Technical data
Electrical connection data
Only use copper lines that are approved for temperatures of min. 180°C/
356°F. When using 4 to 6-core cables, the type of AWG cable specified in
the table increases by one unit.
Example: AWG 12 > AWG 10.
All line cross-section specifications are the minimum cross-sections for the
copper line.
EOS Cubo / Cubo Avantgarde - Installation and Operating Instructions
EN-17
Accessories (optional) Item number
Heater guard rail (to protect unit from being
touched)*, complete
94.6970
Heater guard rail, without wooden parts 94.6972
Stones – caliber 50–100 mm/2–4 in.
ca. 20 kg / ~44 lbs
94.7336
White quartz stones for the Cubo Avantgarde,
ca. 10 kg / ~22 lbs
94.6878
Temperature limiter 160°C/320°F
Use only original replacement parts.
Model: see component
mounted in the device
Heater
power
Connection voltage Connecting cable Fuse
7.5 kW 208 V 12 AWG 30 A
7.5 kW 240 V 12 AWG 15 A
9.0 kW 208 V 12 AWG 35 A
9.0 kW 240 V 12 AWG 20 A
10.5 kW 208 V 12 AWG 20 A
12 kW 208 V 12 AWG 25 A