EasyManua.ls Logo

Epever UP2000-HM6021 - Page 40

Epever UP2000-HM6021
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
38
NO.
Instruction
Setting
10
Equalize
charging time
30M
60M
120M(Default)
180M
11
Equalize
charging
voltage
It cannot be set, which changes depending on the
boost charging voltage.
AGM(Default): 29.2V
GEL: ——
FLD: 29.6V
LFP8: 28.2V
LNCM7: 28.9V
AGM(Default): 58.4V
GEL: --
FLD: 59.2V
LFP15: 53.0V
LFP16: 56.5V
LNCM14: 57.8V
12
Boost
charging
voltage
User define for the 24V system: 21.6~32.0V
Step size: long press for 1V, short press for 0.1V
AGM(Default): 28.8V
GEL: 28.4V
FLD: 29.2V
LFP8: 28.2V
LNCM7: 28.9V
User define for the 48V system: 43.2~64.0V
Step size: long press for 1V, short press for 0.1V
AGM(Default): 57.6V
GEL: 56.8V
FLD: 58.4V
LFP15: 53.0V
LFP16: 56.5V
LNCM14: 57.8V