11.
Hold down the
x
button for at least two seconds while opening the scanner cover. e rollers on the bottom
move momentarily, and then the scanner enters cleaning mode.
e
rollers rotate a bit each time you press the
x
button. Press the
x
button several times to rotate the rollers. Use a genuine Epson cleaning kit or a
so,
moist cloth to clean the rollers as they rotate. Repeat this step until the rollers are clean.
!
Caution:
Be careful not to get your hands or hair caught in the mechanism when operating the roller. is could cause an
injury.
12.
Close the scanner cover.
e scanner exits cleaning mode.
Related Information
& “Cleaning Kit Codes” on page 25
& “Replacing the Roller Assembly Kit” on page 154
Resetting the Number of Scans After Regular Cleaning
Reset the number of scans using Epson Scan 2 Utility aer regular cleaning.
1.
Turn on the scanner.
2.
Start Epson Scan 2 Utility.
Windows 10
Click the start button, and then select EPSON > Epson Scan 2 Utility.
Maintenance
>
Cleaning Inside the Scanner
>
Resetting the Number of Scans After Regular Cleaning