Chapter 3 Disassembly and Assembly
Rev. A
3-1
3
3.2.9 Ribbon Mask Holder Removal
1. Remove [HOUSING, UPPER] (See Section 3.2.1)
2. Remove the Printhead (See Section 3.2.6)
3. Remove the Paper Exit Assy.(See Section 3.2.8)
4. Unhook the cables (to Printhead / PW Detector) from a cable hook on the Carriage Assy.
5. Unhook two tabs fixing the Ribbon Mask Holder to the Carriage Assy., and slightly pulling
it forward.
6. Disconnect the cable from PW Detector attached on the Ribbon Mask Holder, and remove
the Ribbon Mask Holder.
When re-assembling the Ribbon Mask Holder, make sure that the cable of PW
Detector is correctly guided at the back of the Carriage Assy., as shown below, and is
not contacting the CR guide shaft and the paper feed roller assembly.
CHECK POINT
Hooks
(on Carriage ASSY.)
CONNECTOR
(to PW DETECTOR)
RIBBON MASK HOLDER
Figure 3-10. RIBBON MASK HOLDER Removal