EPSON Perfection 1670 Photo/Perfection 1270 Revision B
TROUBLESHOOTING Troubleshooting 10
Table 1-5. The Main Unit Does Not Perform Initialization Operation
Table 1-6. The Carriage Unit Does Not Operate
Table 1-7. The Carriage Operates but the Error Is Displayed
Table 1-8. The Fluorescent Lamp Does Not Turn ON
Table 1-9. The Optional TPU Does Not Operate
Step Cause Check Point Judgment Action
1
Any connector has
come off.
Check all connectors.
If there any
disconnected
connector?
Yes
Connect the
disconnected connector.
No
Replace the I/F Board.
Step Cause Check Point Judgment Action
1
Any connector on the
I/F Board has come
off.
Has any connector on
the I/F Board come
off?
Yes
Connect the connector.
2
The Carriage
Movement
Mechanism is
defective.
• Does the CR Motor
operate when power
is switched ON with
the Upper Housing
of the scanner
removed?
• Does the Carriage
Unit move smoothly
with the CR Motor
removed?
No
Check the Carriage
Movement Mechanism,
and replace the
corresponding part or
disassemble and
reassemble the
Mechanism.
3
The CR Motor is
defective.
Disconnect the
connector on the I/F
Board, and using a
multimeter, measure
the coil resistances
between pins 2 and 4
and between pins 1 and
3 on the Motor side.
Are the resistances at
the two points
approximately 4.8Ω?
No
Replace the CR Motor.
4
The I/F Board is
faulty.
--- --
Replace the I/F Board.
Step Cause Check Point Judgment Action
1
The I/F Board is
faulty.
--- --
Replace the I/F Board.
Step Cause Check Point Judgment Action
1
The connector on the
CCD Board has come
off.
Has the connector on
the CCD Board come
off?
Yes
Replace the Carriage
Unit.
2
The Fluorescent
Lamp is not
connected securely to
the connector on the
Inverter Board.
Is the Fluorescent
Lamp connected
securely on the Inverter
Board?
No
Replace the Carriage
Unit.
3
Replace the Carriage
Unit.
Is there no error after
replacement of the
Carriage Unit?
Yes
Replace the Carriage
Unit.
4
The Main Unit I/F
Board is faulty.
Is there no error after
replacement of the
Carriage Unit?
Yes
Replace the Carriage
Unit.
Step Cause Check Point Judgment Action
1
The Cable of the
optional TPU Unit
has come off.
Has the Connector
CN1 of the I/F Board
come off?
Yes
Connect the Connector
CN1 of the I/F Board.
2
The Main Unit I/F
Board is faulty.
-- --
Replace the I/F Board.
3
The TPU Inverter
Board is faulty.
+24V line: Lamp,
Motor
+5V line: Sensor,
Logic Circuit
--
Replace the optional