EasyManuals Logo

Epson PowerLite S1 User Manual

Epson PowerLite S1
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #59 background imageLoading...
Page #59 background image
59
Projector Care
3 Use the [l][r] buttons to select “Yes,” then press the [e] button.
The lamp operating time will be reset.
Replacing the air filter
Replacing the air filter can also be performed when the projector is mounted
to a ceiling.
1 Turn off the projector power, wait for the cool-down period to
end, then disconnect the power cable.
Cool-down takes about 20 seconds.
2 Push in the tab on the air filter cover and lift up the air filter cover
to remove it.
3 Replace the air filter with a new one.
Take out the old air filter and install the new one. Please ensure there
are no gaps between the air filter and the plastic grill.
4 Replace the air filter cover.
First insert the tabs, and then press down on the opposite side until it
clicks into place.
p
Dispose of used air filters properly in accordance with your local
regulations.

Table of Contents

Other manuals for Epson PowerLite S1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Epson PowerLite S1 and is the answer not in the manual?

Epson PowerLite S1 Specifications

General IconGeneral
BrandEpson
ModelPowerLite S1
CategoryProjector
LanguageEnglish

Related product manuals