Maintenance 9. Troubleshooting
RC700 / RC700-A Rev.23 195
No.
Message
Remedy
Note 1
Note 2
2264
Command argument is out of the
available range. Check the
arguments. Added data 1: Passed
value. Added data 2: argument
order.
For available range of argument, see
the online help. Review the
program.
The Added
value
What
number
argument?
2265
Joint number is out of the available
range.
Available Joint number is from 1 to 6.
Review the program.
The specified
joint number
2266 Wait time is out of available range.
Available wait time is from 0 to
2147483. Review the program.
The specified
wait time
2267
Timer number is out of available
range.
Available timer number is from 0 to
15. Review the program.
The specified
timer number
2268
Trap number is out of available
range.
Available trap number is from 1 to 4.
Review the program.
The specified
trap number
2269
Language ID is out of available
range.
For available language ID, see the
online help. Review the program.
The specified
language ID
2270
Specified D parameter value for the
parallel process is out of available
range.
Available D parameter value is from 0
to 100. Review the program.
The specified
D parameter
value
2271
Arch number is out of available
range.
Available arch number is from 0 to 7.
Review the program.
The specified
arch number
2272
Device No. is out of available
range.
The specified number representing a
control device or display device is out
of available range. For available
device number, see the online help.
Review the program.
The specified
device
number
2273
Output data is out of available
range.
Available output data value is from 0
to 255. Review the program.
Output data
What
number byte
data is out of
range?
2274
Asin argument is out of available
range. Range is from -1 to 1.
Review the program.
2275
Acos argument is out of available
range. Range is from -1 to 1.
Review the program.
2276
Sqr argument is out of available
range.
Review the program.
2277
Randomize argument is out of
available range.
Review the program.
2278
Sin, Cos, Tan argument is out of
available range.
Review the program.
2280
Timeout period set by the TMOut
statement expired before the wait
condition was completed in the
WAIT statement.
Investigate the cause of timeout.
Check whether the set timeout period
is proper.
Timeout
period
2281
Timeout period set by TMOut
statement in WaitSig statement or
SyncLock statement expired.
Investigate the cause of timeout.
Check whether the set timeout period
is proper.
Signal
number
Timeout
period
2282
Timeout period set by TMOut
statement in WaitNet statement
expired.
Investigate the cause of timeout.
Check whether the set timeout period
is proper.
Port number
Timeout
period
2283
Timeout.
Timeout at display device setting.
Reboot the controller.

Table of Contents

Related product manuals