Maintenance 9. Troubleshooting
RC700 / RC700-A Rev.23 207
No.
Message
Remedy
Note 1
Note 2
2860
The force monitor object specified
in the force log is in use.
Specify another force monitor
object.
The same FM number cannot be
specified.
Please specify a different FM
number.
2861
The maximum number of the force
logs is executed.
Review the log timing.
The greatest log number is used.
Please confirm the number of logs.
2862
Failed to allocate memory of force
function.
Reboot the controller.
Please inquire with us if a similar
error occurs after rebooting it.
2863
Execution of force guide sequence,
RecordStart, FCMStart and
LogStart cannot be executed at the
same time.
Please review the program.
Execute after the LogStart property
ends by LogEnd property.
2864
Execution of force guide sequence,
RecordStart, FCMStart and force
monitor cannot be executed at the
same time.
Please quit either.
Execute after quitting the Force
Monitor.
2865
Execution of force guide sequence,
RecordStart, FCMStart and
LogStart cannot be executed at the
same time.
Please review the program.
Execute the LogStart property after
the RecordStart property ends by
force guide sequence, force control
monitor, or the RecordEnd property.
2866
Execution of force guide sequence,
RecordStart, FCMStart and force
monitor cannot be executed at the
same time.
Please quit either.
Execute the force monitor after
quitting the RecordStart property by
force guide sequence, force control
monitor, or the RecordEnd property.
2867
The specified channel in use.
Specify another channel.
The same channel cannot be
specified. Specify a different
channel to execute.
2868
The force monitor object being used
is specified. Please specify another
force monitor object.
The same FM number cannot be
specified. Specify a different FM
number to execute.
2869
The specified duration of
measurement is smaller than the
specified measurement interval.
Check the parameter.
Specify the measurement time larger
than the measurement interval to
execute.
2870
The product of the specified
duration of measurement and the
specified measurement interval is
out of allowable range.
Check the parameter.
Check the measurement time and
interval.
2871
Execution of force guide sequence,
RecordStart, FCMStart, force
monitor cannot be used more than
three at the same time.
To execute newly, make sure to quit
either of the two running items and
execute.
2872
Force monitor cannot be launched
twice.
To start force monitor newly, quit the
running force monitor and start a new
one.