EPSON Stylus Photo R220/R230 Revision A
DISASSEMBLY / ASSEMBLY Disassembly 62
2.3.9 APG Assy. Removal
External View
Figure 2-22. APG Assy. Removal
Parts/Units which should be removed before removing APG Assy.
Paper Support Assy./Housing (left/right)/Housing, Frame/ASF Assy./Main Board
Assy.
Disassembly Procedure
1. Remove the screw that secures the APG Assy. to the Frame, Main, and
remove the assy. avoiding contact with the Frame, Main.
C.B.S. 3x6 (6-8kgf.cm)
APG Assy.
Left Rear Side
When reinstalling the APG Assy.
Make sure that the two tabs and the two dowels are securely
installed to the Frame, Main.
Check if the part indicated in Figure2-23 is inserted in the
slits of the Frame, Main.
Figure 2-23. APG Assy. Installation
APG Assy.
Insert this into the
slit of the Frame,
Main.
Dowels
Tabs