DISASSEMBLY & ASSEMBLY Disassembly/Assembly Procedure (Group 1) 122
4.3.5.2 MOTOR ASSY., ASF
1. Remove the HOUSING, UPPER. (p107)
2. Release the cables of the MOTOR ASSY., ASF from the cable hook.
See Figure 4-41.
3. Disconnect the connector of the MOTOR ASSY., ASF, shown in
Figure 4-41
from the
relay connector.
4. Remove the two screws that secure the MOTOR ASSY., ASF and remove the MOTOR
ASSY., ASF.
See Figure 4-42.
Two C.B.P. 3 x 8 screws (6 ± 1 kgf.cm)
Figure 4-41. Releasing the cables of the MOTOR ASSY., ASF
Figure 4-42. Removing the screws from the MOTOR ASSY., ASF
C H E C K
P O I N T
Put a screwdriver (with a 60 mm or longer shaft is recommended)
through the holes on the FRAME ASSY., SUB, RIGHT to remove
the C.B.P 3x8 screws that secure the MOTOR ASSY., ASF as
shown in Figure 4-42.
Be sure to insert the guide pin of the ASF into the positioning
hole of the MOTOR ASSY., ASF.
Secure the grounding terminal and the MOTOR ASSY., ASF
together with the C.B.S. 3 x 8 screw at the rear as shown in
Figure 4-42.
positioning point
MOTOR ASSY., ASF
cable hook
relay connector
Left rear side of the printer
MOTOR ASSY., ASF
C.B.P. 3x8
The MOTOR ASSY.,
ASF and the grounding
terminal are secured
together.
Put the screwdriver
through this hole.
Right side of the printer
Grounding Wire
(MOTOR ASSY., ASF)