Cleaning PG Adjustment
Purpose: The Cleaning PG adjustment measures the gap between the Print Head’s Nozzle Plate and the AID Grid
located on the Flushing Box.
Note: There are 2 possible settings for the Cleaning PG adjustment. (2.2 Stop and 2.8 Stop)
Overview
1. Select 2.2 Stop.
2. Test the AID Components using the AID Check function.
2.1 If the AID Check indicates a working system, the adjustment is completed.
2.2 If the AID Check fails, continue to step 3.
3. Select 2.8 Stop.
4. Test the AID Components using the AID Check function.
4.1 If the AID Check indicates a working system, the adjustment is completed.
4.2 If the AID Check fails, troubleshoot all components.
How to set 2.2 Stop and 2.8 Stop
(Detail on the following pages)