Settings/Maintenance
37
Calibration
Click Calibration (0341) from Color Calibration (034) to display the screen.
You can perform calibration by using the following work flow.
Create Correction
Value
Print Print a correction chart: Prints a chart for adjustment.
Measure Color Measure color for the correction chart:
Perform color measurement for the printed chart on the Client PC with a
connected color measurement device.
Create Correction Value Creating a correction value: Create a correction value file.
Correction Value
Verification
Print Print a verification chart: Prints a verification chart.
Measure Color Measure color for the verification chart:
Perform color measurement for the printed chart on the Client PC with a
connected color measurement device.
Write Verify correction accuracy:
Verify the accuracy of the created correction value to complete the
correction value file creation process.
Tip:
O After adjusting values for Gray Adjustment, perform Color Calibration, and then make the settings again.
U “Gray Adjustment” on page 47
O Click Date of Adjustment to display the time when it was last adjusted. You can check the changed date settings for
each Paper Surface Type.