Maintenance 18. Controller Unit
234 VT Rev.1
(
3)
Fix the controller unit to
the base.
Hexagon socket head cap bolts:
3-M4×10 (with a plain washer)
Tightening torque: 4.0 ± 0.2 N·m
(
4)
Connect
the TP connector inside the connector plate.
(
5)
M
ount the connector plate.
Reference: Maintenance 7.7 Connector Plate