26
Normal Sensor: In , when normal Sensors are triggered the system will alarm. Arm Mode
In disarm mode, when normal Sensors are triggered, the system will not alarm.
24 Hour Sensor: When 24 hour Sensors are triggered, the system will alarm regardless
of the alarm status.
Delay Sensor: In , when delay Sensors are triggered, the system will alarm Arm Mode
immediately after the set delay time has expired. (For "Entry Delay", please refer to page
29.
Home Sensor: In , only normal Sensors will be triggered, home Sensors will Home Mode
not be triggered - this allows for freedom of movement i
n selected areas of the property
even when the system is armed.
Sensor Naming
To rename a Sensor, select “Edit Sensor Name” in step 5 and press . Then input [Enter]
the Sensor name.
Pairing a New Wireless Siren
Siren sold separately.
Enter the Siren into ‘pairing state’ (for ‘pairing’ instructions please refer to the relevant
Siren Instruction manual).
Press or on the Control Panel to send out a pairing signal to the [Disarm ] [SOS]
Siren. A beep heard from the Siren indicates successful pairing. If two beeps are heard,
the Siren has already been paired.
Test Mode
To test that Sensors and Remote Controls are connected to the Control Panel
Log into the menu, press or , choose ‘Accessories’, press .[ ] [ ] [Enter]
Press or , choose “Test Mode”, press . LCD display will show “Yes?”, [ ] [ ] [Enter]
press again to acrtivate Test Mode for 10 minutes.[Enter]
Trigger linked Sensors one by one, the triggered Sensors will transmit signals to the
Control Panel. When 3 beeps are heard the Control Panel will count how many
Sensors have been triggered and display the number on the screen. Exit by pressing
the [Esc] button.
Note: [*] In the event of incorrectly inputting the name press the button on the Control Panel to
clear down and start again . Press the to exit.[ESC]