EasyManua.ls Logo

Ericsson CME 20 R6.1 - Operational Conditions

Ericsson CME 20 R6.1
307 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Diversity Supervision
17.4 Operational Conditions
The diversity supervision is characterised by a number of parameters
which are implemented as software constants. The parameter values are
selected so that the risk of false disturbances during normal operation is
negligible:
Table 15 Preliminary diversity supervision parameters
Observation period 5 minutes
Channel utilisation threshold -96 dBm
Minimum channel utilisation ratio 5%
Disturbance threshold 12 dB
The disturbance filter characteristics will give the time to alarm. If
100% of the observation periods causes a disturbance, the time to alarm
will be 50 minutes. If the disturbance ratio is less than 50% no alarm
will be raised.
If 100% of the observation periods indicates no disturbance, the alarm
will be terminated after 100 minutes. If the disturbance ratio is more
than 15%, the alarm will not be terminated.
EN/LZT 123 2697 R5A
1998-08-13
123 (306)
© Ericsson Radio Systems AB
All Rights Reserved

Table of Contents