Ericsson CME 20 R6.1 - Product Requirements

Ericsson CME 20 R6.1
307 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Product Specification for RBS 2301
4.6.4 Operator Interface
When opening the Mounting Base there is an MMI area available
containing the operational interface which includes the LED’s and
buttons listed below.
Indicators (LEDs)
Fault One or more faults, equals BS fault.
Operational At least one TRX operational.
Local mode RBS in local mode.
Reduced capacity One of two TRX’s operational.
Test TRX1 Result from TRX1 test operation.
Test TRX2 Result from TRX2 test operation.
AC Power on AC Power is switched on to RBS.
Battery fault Lowbattery DC voltage, battery absent.
External alarm One or more external alarm active.
Buttons
CPU reset
Local/remote mode
Test Operation initiation
Switches
Battery
AC Mains
Barcodes Signs
The bar code sign for product identification is readable without
disturbing the RBS function.
4.7 Product Requirements
4.7.1 Appearance
Ericsson products are designed to appear as one physical unit,
inconspicuous, pleasant and good-looking. The standard colour of the
RBS is Grey.
The front cover of the RBS which is designed as a sun-shield may be
ordered in different colours to make the RBS even more inconspicuous.
There is an optional integrated antenna system which will support the
idea that the RBS and antenna site are the same.
46 (306)
EN/LZT 123 2697 R5A
1998-08-13
© Ericsson Radio Systems AB
All Rights Reserved