EasyManua.ls Logo

Ericsson CME 20 R6.1 - Basic Configuration GSM 1800 Mhz, M18 D_1.2

Ericsson CME 20 R6.1
307 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Radio Configurations, RBS 2000 Micro
3.9 Basic Configuration GSM 1800 MHz, M18d_1.2
Ant.
output
TX / RX
X
V
TX2
TX1
RXA
RXB
RXA
RXB
CDU
07_0348a
MultiCasting
Box
50
ohm
X
X
TRX
TRX
RXDA
<
RXDA
<
FILTER
UNIT
DUPLEX
Figure 15 Basic Configuration M18d_1.2
3.9.1 Characteristics M18d_1.2
Max. no. of TRXs 2
No. of feeders 1
No. of antennas 1
Antenna configuration TX/RX
Loss TRX-TX Reference point Max. 4.5 dB in each output/input
Limitations No RX diversity
3.9.2 Capacity M18d_1.2 (with Multicasting Box)
The capacity is defined at the Tx and Rx reference points marked with
X.
Capacity Radio Transmission: The output power from 1 TX to each TX/
RX output/input is minimum +27.5 dBm.
Capacity Radio Reception: The actual sensitivity level is 99.5 dBm,
or better.
EN/LZT 123 2697 R5A
1998-08-13
33 (306)
© Ericsson Radio Systems AB