BTS Parameter Limitations
44 BTS Parameter Limitations
This chapter specifies configurable BTS parameters with limitations
compared with the parameter ranges in the Abis O&M IWD. BTS
parameters with no limitations compared to the Abis O&M IWD are not
stated in this chapter.
44.1 Purpose and Readers
The purpose is to show BTS parameters with parameter range
limitations compared to the Abis O&M IWD.
People involved in the preparation of data transcripts for the BSC are
the target group of this specification.
44.2 Terminology
See 3/155 19–ANT 241 05 Uen, Abis O&M Interface, Part I, Model.
44.3 References
See 4/155 19–ANT 241 05 Uen, Abis O&M Interface, Part II,
Procedures.
44.4 Parameters
The parameters listed are extracted from the Data Elements listed in the
Abis O&M IWD document (see ref. 1). This chapter states the BTS
parameters with parameter range limitations compared with the Abis
O&M IWD.
For each parameter in the list, the range supported by the BTS and the
Abis O&M IWD is stated.
All coding in the document is in hexadecimal (hex) representation if
nothing else is stated.
44.4.1 Accordance Indication
BTS-supported value range:
AIP: 0 - 1
IWD-defined value range: 0 - 2
44.4.2 Alarm Status Type
BTS-supported value range:
Alarm status type: 1
IWD
IWD-defined value range: 0 - 1