EasyManua.ls Logo

Ericsson CME 20 R6.1 - Page 291

Ericsson CME 20 R6.1
307 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
BTS Parameter Limitations
44.4.3 BS_AG_BLKS_RES
BTS-supported value range:
BS_AG_BLKS_RES: 0 - 1
IWD-defined value range: 0 - 7
44.4.4 CON Connection List
BTS supported value range:
y 0 -12
mi 2 - 13
CCP
CCP number 256, 260, ... 348
Reserved 0 - 255, 257 - 259, 261 - 263,
... 349 - 1023
Tag CP gives deconcentrated inlet/outlet 0
CP gives concentrated inlet/outlet and
Tag=sequential number of CG within
Input Concentration Map
1-12
IWD defined value range:
y0-16
mi 2 - 17
CCP
CCP number 0, 4, ... 1020
Reserved 1- 3, 5 - 7, ... 1021 - 1023
Tag CP gives deconcentrated inlet/outlet 0
CP gives concentrated inlet/outlet and
Tag=sequential number of CG within
Input Concentration Map
1-16
44.4.5 Extended Range Indicator
BTS-supported parameter range:
ERI: 0 (extended range off )
IWD-defined value range: 0 - 1
290 (306)
EN/LZT 123 2697 R5A
1998-08-13
© Ericsson Radio Systems AB
All Rights Reserved

Table of Contents