Loading...
Radio Configurations, RBS 2000 Micro
3.10 Basic Configuration GSM 1900 MHz, M19d_2.2
Ant.
TX1 / RXA
X
V
X
V
TX2
TX1
RXA
RXB
RXA
RXB
09_0348a
TX2 / RXB
TRX
TRX
RXDA
<
RXDA
<
FILTER
UNIT
DUPLEX
Figure 16 Basic Configuration M19d_2.2
3.10.1 Characteristics M19d_2.2
Max. no. of TRXs 2
No. of feeders 2
No. of antennas 2
Antenna configuration TX/RX + TX/RX
3.10.2 Capacity M19d_2.2
The capacity is defined at the Tx and Rx reference points marked with
X.
Capacity Radio Transmission: The output power with 1 TX to one TX/
RX output is minimum +32 dBm.
The equivalent output power with TX
diversity configured is minimum +35 dBm.
Capacity Radio Reception: The actual sensitivity level is 104 dBm,
or better.
34 (306)
EN/LZT 123 2697 R5A
1998-08-13
© Ericsson Radio Systems AB
All Rights Reserved

Table of Contents